
Add to Cart
Introduction
A monitor module is a device used in addressable fire alarm systems to interface with and monitor the status of other connected devices or systems.
The key functions of an input module include:
Monitoring Inputs:
The input module is connected to various system components, such as sprinkler flow switches, tamper switches, or other auxiliary devices.
It monitors the status of these connected inputs and relays that information to the fire alarm control panel.
Reporting Status:
When the input module detects a change in the status of a connected device (e.g., a sprinkler flow switch activating), it communicates this information to the fire alarm control panel.
This allows the control panel to accurately track the status of various fire protection and life safety systems.
Addressability:
Like other addressable devices, each input module has a unique digital address recognized by the fire alarm control panel.
This enables the control panel to identify the specific location and source of any reported alarm or supervisory signals.
Supervised Monitoring:
Input modules are typically configured to monitor their connected inputs for both normal and abnormal conditions, such as open circuits or short circuits.
This supervisory monitoring helps ensure the integrity of the overall fire alarm system.
Integration with Other Systems:
Input modules can be used to interface the fire alarm system with other building systems, like HVAC controls or elevator recall, allowing for coordinated emergency response.
So in summary, the terms "input module" and "monitor module" are used interchangeably to refer to these addressable devices that provide input monitoring and status reporting capabilities within a fire alarm system.
Product name | Input Module | Type | Addressable |
Loop Bus wired | 2-wire Non-polarized | Monitor Current | ≤350uA |
Alarm Currrent | ≤2mA | Dimension | Φ85*40 mm |
Work voltage | DC17V~DC33V | Operating Environment | Temperature -10°C~+50°C Humidity ≤95%. |
Weight | Weight:60g(with base) | Certification | CE |
Connection between Input Module
Connection Diagram of Fire Alarm System
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.