Shenzhen Xinhe'an Technology Co., Ltd.

Fire Safety, Protect Your Life and Property Safety.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Conventional Fire Alarm System /

Conventional Heat Detector – Fire Alarm System for Building Safety & Fire Prevention​

Contact Now
Shenzhen Xinhe'an Technology Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsClaire
Contact Now

Conventional Heat Detector – Fire Alarm System for Building Safety & Fire Prevention​

Ask Latest Price
Video Channel
Brand Name :XHA
Model Number :XHA8025
Certification :CE
Place of Origin :China
MOQ :1
Price :negotiable
Payment Terms :T/T,Western Union
Supply Ability :10000PCS/Month
Delivery Time :3 Working days
Packaging Details :100pcs/carton
Size :103*103*55mm
Product Type :2 Wire Heat Detector
Weight :105 g
Name :Conventional Heat Detector
Humidity Range :10% to 95% non-condensing
Apaitplicon :Fire Alarm System
Standby Current :≤80µA @ 24 VDC
Operating Temperature :0-50°C
more
Contact Now

Add to Cart

View Product Description

Conventional Heat Detector For Fire Alarm Fire Detection System In Building

Conventional Heat Detector – Fire Alarm System for Building Safety & Fire Prevention​

Introduction

This Heat detector consists of the following key components:

Sensing Element:
The sensing element is the core component that detects changes in temperature.
It can use either a fixed temperature or a rate-of-rise principle to detect heat.
Fixed temperature detectors activate the alarm when the temperature reaches a predetermined threshold.
Rate-of-rise detectors activate the alarm when the temperature rises at a rapid rate, indicating a potential fire.


Alarm Horn/Sounder:
When the sensing element detects a rise in temperature, the heat detector activates a loud audible alarm, typically a high-decibel beeping or buzzing sound.
The alarm is intended to wake up and alert occupants to the presence of a heat source, prompting them to evacuate the area.


Power Source:
Conventional heat detectors can be powered by a hardwired connection to the building's electrical system.

Status Indicators:
Heat detectors often have visual status indicators, such as LED lights, to provide feedback on the device's operational status.
These indicators can signal issues like low battery, sensor malfunctions, or normal operation.


Mounting:
Conventional heat detectors are typically mounted on the ceiling or high on walls, as heat rises and accumulates at the ceiling level.
The mounting hardware allows for easy installation and replacement of the detector as needed.


Parameters

Product Name Heat Detector Rated operational voltage 9 to 28VDC Volts
Wired 2 Wired, Non-polarized Static current ≤80µA @ 24 VDC
Alarm current 20mA @ 24 VDC Work temperature -10°C~+50°C
Certification CE Humidity ≤95%.
Size 103*103*55mm Weight 105 g

Feature

Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.

SMD circuit board design-satisfactory quality and reliability guaranteed

They work perfectly with all conventional intelligent fire control panels
Key Specifications/Special Features
Advanced MCU Expert Algorithm Software.
Durable sensor head, no need for replacement

Easy installation and maintenance

Installation


INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.

Conventional Heat Detector – Fire Alarm System for Building Safety & Fire Prevention​

Conventional Heat Detector – Fire Alarm System for Building Safety & Fire Prevention​


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.




Inquiry Cart 0
You May Like
2 Wire Conventional Fire Alarm System Wall  Mount With Sound And Light Alarm
2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke Alarm
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm System
2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm System
4 Zone 8 Zone 16 Zone Conventional Fire Alarm System For Industrial Buildings
4 Zone 8 Zone 16 Zone Conventional Fire Alarm System For Industrial Buildings
Conventional 2 Zone Fire Alarm Panel
Conventional 2 Zone Fire Alarm Panel
EN54 2 Wire Smoke Alarm
EN54 2 Wire Smoke Alarm
Conventional Smoke Detector
Conventional Smoke Detector
EN54 Conventional 2 Wire Smoke Detector For Fire Secuirty Fire Alarm System
EN54 Conventional 2 Wire Smoke Detector For Fire Secuirty Fire Alarm System
EN54 Standard Conventional Fire Alarm System 2 Wire Smoke Alarm
EN54 Standard Conventional Fire Alarm System 2 Wire Smoke Alarm
24V Fire Alarm Bell Loud Sounder for Smoke Detector Fire Safety Systems Humidity Range 10-95% Temperature Range -10-50°C
24V Fire Alarm Bell Loud Sounder for Smoke Detector Fire Safety Systems Humidity Range 10-95% Temperature Range -10-50°C
8 Zone Conventional Fire Alarm Controller Red For Fire Safety Alarm System
8 Zone Conventional Fire Alarm Controller Red For Fire Safety Alarm System
24VDC Synchronized Alarm Bell – Addressable Wall Mount for Commercial Smoke Detection Systems
24VDC Synchronized Alarm Bell – Addressable Wall Mount for Commercial Smoke Detection Systems
16 Zone Conventional Fire Alarm Panel AC220V Powered XHA1016
16 Zone Conventional Fire Alarm Panel AC220V Powered XHA1016
4 Zone Conventional Fire Alarm Panel Metal Material Customized
4 Zone Conventional Fire Alarm Panel Metal Material Customized
Send your message to this supplier
*From:
*To:

Shenzhen Xinhe'an Technology Co., Ltd.

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now